Micropile Building Foundations
Allentown, Pennsylvania
JG designed and installed 114 micropiles to support a new office building at the Waterfront Development in Allentown, Pennsylvania. The piles were designed for 300 kips in compression and averaged approximately 70 feet deep. Micropiles were required for foundation support for this project due to the existing fill materials at the site, along with the karst topography underlying the fill. JG also performed a micropile load test with a 600 kip maximum test load.